Physical Properties | Metric | English | Comments |
---|---|---|---|
Density | 1.19 g/cc | 0.0430 lb/in³ | ISO 1183/A |
Mechanical Properties | Metric | English | Comments |
---|---|---|---|
Hardness, Shore D | 78 | 78 | Conditioned; ISO 868 |
85 | 85 | ISO 868 | |
Tensile Strength at Break | 50.0 MPa | 7250 psi | Conditioned; ISO R 527 |
60.0 MPa | 8700 psi | ISO R 527 | |
Elongation at Break | 3.0 % | 3.0 % | ISO R 527 |
15 % | 15 % | Conditioned; ISO R 527 | |
Modulus of Elasticity | 2.00 GPa | 290 ksi | Conditioned; ISO 178 |
3.50 GPa | 508 ksi | ISO 178 | |
Izod Impact, Notched (ISO) | 3.00 kJ/m² | 1.43 ft-lb/in² | ISO 180/1A |
8.00 kJ/m² | 3.81 ft-lb/in² | Conditioned; ISO 180/1A | |
Charpy Impact Unnotched | 4.00 J/cm² | 19.0 ft-lb/in² | ISO 179/IeU |
NB | NB | Conditioned; ISO 179/IeU | |
Charpy Impact, Notched | 0.250 J/cm² | 1.19 ft-lb/in² | ISO 179/IeA |
0.700 J/cm² | 3.33 ft-lb/in² | Conditioned; ISO 179/IeA |
Thermal Properties | Metric | English | Comments |
---|---|---|---|
Melting Point | 260 °C | 500 °F | ISO 3146/C2 |
Deflection Temperature at 1.8 MPa (264 psi) | 85.0 °C | 185 °F | ISO 75-2/AF |
Flammability, UL94 | V-0 @Thickness 0.800 mm |
V-0 @Thickness 0.0315 in |
|
Oxygen Index | 38 % | 38 % | ISO 4589 |
Glow Wire Test | 960 °C | 1760 °F | CEI 60695/2/1 |
Electrical Properties | Metric | English | Comments |
---|---|---|---|
Volume Resistivity | 1.00e+14 ohm-cm | 1.00e+14 ohm-cm | Conditioned; CEI 60093 |
1.00e+15 ohm-cm | 1.00e+15 ohm-cm | CEI 60093 | |
Surface Resistance | 1.00e+14 ohm | 1.00e+14 ohm | Conditioned; CEI 60093 |
1.00e+15 ohm | 1.00e+15 ohm | CEI 60093 | |
Dielectric Strength | 28.0 kV/mm | 711 kV/in | CEI 60243-1 |
Comparative Tracking Index | >= 600 V | >= 600 V | CEI 60112/Solution A |