Songhan Plastic Technology Co.,Ltd.
 POLYMER SEARCH

Hippe SI GC 202 Woven Glass Cloth Reinforced Silicone Resin - Sheet

Category Polymer , Thermoset , Silicone , Silicone, Molded, Glass Fiber Filled
Manufacturer Erhard Hippe KG
Trade Name
Port Shanghai port,China
Trade Terms FOB, CFR, CIF
Payment Terms L/C, T/T, Western Union
Download PDF Hippe SI GC 202 Woven Glass Cloth Reinforced Silicone Resin - Sheet.pdf
Price EMAIL US    sales@lookpolymers.com
  Online Service   lookpolymers   27660005
Material Notes:
Used in mechanical and electrical applications at elevated temperature. Good heat resistance.Information provided by Hippe.
Physical Properties Metric English Comments
Specific Gravity 1.60 - 1.90 g/cc
1.60 - 1.90 g/cc
IEC 1212-2 8.1
Mechanical Properties Metric English Comments
Tensile Strength >= 90.0 MPa
>= 13100 psi
IEC 1212-2 5.7
Flexural Strength >= 120 MPa
>= 17400 psi
Perpendicular to laminations; IEC 1212-2 5.1
Flexural Modulus >= 13.0 GPa
>= 1890 ksi
IEC 1212-2 5.2
Compressive Strength >= 160 MPa
>= 23200 psi
Perpendicular to laminations; IEC 1212-2 5.3
Shear Strength >= 20.0 MPa
>= 2900 psi
Parallel to laminations; IEC 1212-2 5.6
Izod Impact, Unnotched (ISO) >= 26.0 kJ/m²
>= 12.4 ft-lb/in²
Parallel to laminations; IEC 1212-2 5.5.3
Charpy Impact Unnotched >= 2.50 J/cm²
>= 11.9 ft-lb/in²
Parallel to laminations; IEC 1212-2 5.5.2
Thermal Properties Metric English Comments
Flammability, UL94 V-0
V-0
IEC 1212-2 7.2
Electrical Properties Metric English Comments
Insulation Resistance >= 1.00e+9 ohm
>= 1.00e+9 ohm
After immersion in water; IEC 1212-2 6.3
Dielectric Constant <= 6.0

@Frequency 48.0 - 62.0 Hz
<= 6.0

@Frequency 48.0 - 62.0 Hz
IEC 1212-2 6.2
<= 6.0

@Frequency 1.00e+6 Hz
<= 6.0

@Frequency 1.00e+6 Hz
IEC 1212-2 6.2
Dielectric Breakdown >= 25000 V

@Temperature 90.0 °C
>= 25000 V

@Temperature 194 °F
In oil, parallel to laminations; IEC 1212-2 6.2
Dissipation Factor <= 0.070

@Frequency 48.0 - 62.0 Hz
<= 0.070

@Frequency 48.0 - 62.0 Hz
IEC 1212-2 6.2
<= 0.070

@Frequency 1.00e+6 Hz
<= 0.070

@Frequency 1.00e+6 Hz
IEC 1212-2 6.2
Comparative Tracking Index >= 450 V
>= 450 V
IEC 1212-2 6.4
Descriptive Properties Value Comments
Thermal Endurance 180 T.I.
IEC 1212-2 7.1
Water Absorption < 75 mg
IEC 1212-2 8.2; Test piece 50 x 50 x 10 mm
Copyright © lookpolymers.com All Rights Reserved