Category | Polymer |
Manufacturer | Fujipoly Industries |
Trade Name | Sarcon® |
Port | Shanghai port,China |
Trade Terms | FOB, CFR, CIF |
Payment Terms | L/C, T/T, Western Union |
Download PDF | Fujipoly Industries Sarcon® NR-c Gap Filler Pad Non-Silicone.pdf |
Price | EMAIL US sales@lookpolymers.com |
Physical Properties | Metric | English | Comments |
---|---|---|---|
Specific Gravity | 2.10 g/cc | 2.10 g/cc | JIS-K-6220; ASTM D-792 |
2.10 g/cc | 2.10 g/cc | -40°C for 1,000 hrs; JIS-K-6220; ASTM D 792 | |
2.10 g/cc | 2.10 g/cc | -40°C for 30 min and 125°C for 30 min. for 1,000 times; JIS-K-6220; ASTM D 792 | |
2.10 g/cc | 2.10 g/cc | 85°C for 1,000 hrs with 85% RH; JIS-K-6220; ASTM D 792 | |
2.10 g/cc | 2.10 g/cc | 80°C for 1,000 hrs; JIS-K-6220; ASTM D 792 | |
2.20 g/cc | 2.20 g/cc | 125°C for 1,000 hrs; JIS-K-6220; ASTM D 792 |
Mechanical Properties | Metric | English | Comments |
---|---|---|---|
Hardness, Shore C | 28 | 28 | 85°C for 1,000 hrs with 85% RH; SRIS0101S |
30.0 | 30.0 | -40°C for 1,000 hrs; SRIS0101S | |
30 | 30 | 80°C for 1,000 hrs; SRIS0101S | |
37.0 | 37.0 | -40°C for 30 min and 125°C for 30 min. for 1,000 times; SRIS0101S | |
55 | 55 | 125°C for 1,000 hrs; SRIS0101S | |
Hardness, Shore OO | 53 | 53 | ASTM D-2240 |
Tensile Strength, Yield | 0.200 MPa | 29.0 psi | 85°C for 1,000 hrs with 85% RH; JIS-K-6251(#2); ASTM D412 |
0.200 MPa | 29.0 psi | -40°C for 1,000 hrs; JIS-K-6251(#2); ASTM D412 | |
0.200 MPa | 29.0 psi | JIS-K-6251(#2)/ASTM D-412 | |
0.300 MPa | 43.5 psi | 80°C for 1,000 hrs; JIS-K-6251(#2); ASTM D412 | |
0.800 MPa | 116 psi | 125°C for 1,000 hrs; JIS-K-6251(#2); ASTM D412 | |
0.800 MPa | 116 psi | -40°C for 30 min and 125°C for 30 min. for 1,000 times; JIS-K-6251(#2); ASTM D412 | |
Elongation at Yield | 20 % | 20 % | 125°C for 1,000 hrs; JIS-K-6251(#2); ASTM D412 |
25.0 % | 25.0 % | -40°C for 30 min and 125°C for 30 min. for 1,000 times; JIS-K-6251(#2); ASTM D412 | |
150 % | 150 % | JIS-K-6251(#2)/ASTM D-412 | |
180 % | 180 % | 80°C for 1,000 hrs; JIS-K-6251(#2); ASTM D412 | |
180 % | 180 % | 85°C for 1,000 hrs with 85% RH; JIS-K-6251(#2); ASTM D412 | |
180 % | 180 % | -40°C for 1,000 hrs; JIS-K-6251(#2); ASTM D412 | |
Tear Strength | 1.50 kN/m | 8.56 pli | JIS-K-6252 (Angle)/ASTM D-624 |
1.70 kN/m | 9.70 pli | -40°C for 1,000 hrs; JIS-K-6252(Angle); ASTM D624 | |
1.80 kN/m | 10.3 pli | 80°C for 1,000 hrs; JIS-K-6252(Angle)/ASTM D 624 | |
2.00 kN/m | 11.4 pli | 85°C for 1,000 hrs with 85% RH; JIS-K-6252(Angle); ASTM D 624 | |
5.70 kN/m | 32.5 pli | -40°C for 30 min and 125°C for 30 min. for 1,000 times; JIS-K-6252(Angle); ASTM D 624 | |
7.40 kN/m | 42.2 pli | 125°C for 1,000 hrs; JIS-K-6252 (Angle); ASTM D 624 |
Thermal Properties | Metric | English | Comments |
---|---|---|---|
Thermal Conductivity | 1.50 W/m-K | 10.4 BTU-in/hr-ft²-°F | JIS-R-2618; ASTM D2326 |
Maximum Service Temperature, Air | 105 °C | 221 °F | |
Minimum Service Temperature, Air | -40.0 °C | -40.0 °F | |
Flammability, UL94 | V-0 | V-0 |
Electrical Properties | Metric | English | Comments |
---|---|---|---|
Volume Resistivity | 7.00e+6 ohm-cm | 7.00e+6 ohm-cm | -40°C for 1,000 hrs; JIS-K-6249; ASTM D257 |
2.00e+11 ohm-cm | 2.00e+11 ohm-cm | JIS-K-6249/ASTM D257 | |
8.00e+11 ohm-cm | 8.00e+11 ohm-cm | 85°C for 1,000 hrs with 85% RH; JIS-K 6249; ASTM D257 | |
1.00e+12 ohm-cm | 1.00e+12 ohm-cm | -40°C for 30 min and 125°C for 30 min. for 1,000 times; JIS-K-6249; ASTM D149 | |
2.00e+12 ohm-cm | 2.00e+12 ohm-cm | 80°C for 1,000 hrs; JIS-K-6249; ASTM D 257 | |
3.00e+13 ohm-cm | 3.00e+13 ohm-cm | 125°C for 1,000 hrs; JIS-K-6249; ASTM D257 | |
Dielectric Strength | 9.00 kV/mm | 229 kV/in | -40°C for 1,000 hrs; JIS-K-6249; ASTM D149 |
11.0 kV/mm | 279 kV/in | JIS-K-6249; ASTM D-149 | |
18.0 kV/mm | 457 kV/in | 80°C for 1,000 hrs; JIS-K-6249; ASTM D 149 | |
26.0 kV/mm | 660 kV/in | 125°C for 1,000 hrs; JIS-K-6249; ASTM D 149 | |
27.0 kV/mm | 686 kV/in | -40°C for 30 min and 125°C for 30 min. for 1,000 times; JIS-K-6249; ASTM D 149 |
Descriptive Properties | Value | Comments |
---|---|---|
Color | Grey |