Category | Polymer , Film , Thermoplastic , Polyester, TP , PVDC , Polyvinyl Dichloride (PVDC) Coated Polyester Film |
Manufacturer | DuPont Teijin Films (DTF) |
Trade Name | Mylar® |
Port | Ningbo port,China |
Trade Terms | FOB, CFR, CIF |
Payment Terms | L/C, T/T, Western Union |
Download PDF | DuPont Teijin Films Mylar® M34 Polyester Film, 50 Gauge (13 µm), PVDC Coated.pdf |
Price | EMAIL US sales@lookpolymers.com |
Physical Properties | Metric | English | Comments |
---|---|---|---|
Density | 1.40 g/cc | 0.0506 lb/in³ | Average value for Mylar® films. |
Moisture Vapor Transmission | 0.120 cc-mm/m²-24hr-atm | 0.305 cc-mil/100 in²-24hr-atm | ASTM E96 Procedure E |
Water Vapor Transmission | 9.00 g/m²/day | 0.580 g/100 in²/day | ASTM E96 Procedure E |
Oxygen Transmission | 0.100 cc-mm/m²-24hr-atm | 0.254 cc-mil/100 in²-24hr-atm | or 9 cc/m²-24hr-atm for the film. ASTM D3985 |
Mechanical Properties | Metric | English | Comments |
---|---|---|---|
Film Elongation at Break, MD | 110 % | 110 % | ASTM D882 |
Film Elongation at Break, TD | 70 % | 70 % | ASTM D882 |
Modulus of Elasticity | 3.45 GPa | 500 ksi | (stiffness), ASTM D882 |
Tear Strength Test | 300 | 300 | Graves, g; ASTM D1004 |
Seal Strength | 156 g/25 mm | 156 g/in | |
Film Tensile Strength at Break, MD | 186 MPa | 27000 psi | ASTM D882 |
Film Tensile Strength at Break, TD | 228 MPa | 33100 psi | ASTM D882 |
Thermal Properties | Metric | English | Comments |
---|---|---|---|
Maximum Service Temperature, Air | 121 °C | 250 °F | Not cleared by FDA for food temperatures above this temperature. |
Shrinkage | 1.5 % @Temperature 150 °C, Time 1800 sec |
1.5 % @Temperature 302 °F, Time 0.500 hour |
Film shrinkage in oven. |
Optical Properties | Metric | English | Comments |
---|---|---|---|
Haze | 7.0 % | 7.0 % | ASTM D1003 |
Gloss | 140 % | 140 % | 20°; ASTM D2457 |
Transmission, Visible | 90 % | 90 % | transparent; thickness not quantified |