Category | Polymer , Thermoset , Polyester, TS , Thermoset Polyester Glass Filled BMC |
Manufacturer | Erhard Hippe KG |
Trade Name | |
Port | Ningbo port,China |
Trade Terms | FOB, CFR, CIF |
Payment Terms | L/C, T/T, Western Union |
Download PDF | Hippe UP GM 204 Woven Glass Mat Reinforced Polyester (unsaturated) Resin - Sheet.pdf |
Price | EMAIL US sales@lookpolymers.com |
Physical Properties | Metric | English | Comments |
---|---|---|---|
Specific Gravity | 1.50 - 1.90 g/cc | 1.50 - 1.90 g/cc | IEC 1212-2 8.1 |
Mechanical Properties | Metric | English | Comments |
---|---|---|---|
Tensile Strength | >= 120 MPa | >= 17400 psi | IEC 1212-2 5.7 |
Flexural Strength | >= 250 MPa | >= 36300 psi | Perpendicular to laminations; IEC 1212-2 5.1 |
Flexural Modulus | >= 10.0 GPa | >= 1450 ksi | IEC 1212-2 5.2 |
Compressive Strength | >= 250 MPa | >= 36300 psi | Perpendicular to laminations; IEC 1212-2 5.3 |
Shear Strength | >= 20.0 MPa | >= 2900 psi | Parallel to laminations; IEC 1212-2 5.6 |
Izod Impact, Unnotched (ISO) | >= 44.0 kJ/m² | >= 20.9 ft-lb/in² | Parallel to laminations; IEC 1212-2 5.5.3 |
Charpy Impact Unnotched | >= 5.00 J/cm² | >= 23.8 ft-lb/in² | Parallel to laminations; IEC 1212-2 5.5.2 |
Electrical Properties | Metric | English | Comments |
---|---|---|---|
Insulation Resistance | >= 5.00e+8 ohm | >= 5.00e+8 ohm | After immersion in water; IEC 1212-2 6.3 |
Dielectric Constant | <= 4.5 @Frequency 48.0 - 62.0 Hz |
<= 4.5 @Frequency 48.0 - 62.0 Hz |
IEC 1212-2 6.2 |
<= 4.5 @Frequency 1.00e+6 Hz |
<= 4.5 @Frequency 1.00e+6 Hz |
IEC 1212-2 6.2 | |
Dielectric Breakdown | >= 35000 V @Temperature 90.0 °C |
>= 35000 V @Temperature 194 °F |
In oil, parallel to laminations; IEC 1212-2 6.2 |
Dissipation Factor | <= 0.050 @Frequency 48.0 - 62.0 Hz |
<= 0.050 @Frequency 48.0 - 62.0 Hz |
IEC 1212-2 6.2 |
<= 0.050 @Frequency 1.00e+6 Hz |
<= 0.050 @Frequency 1.00e+6 Hz |
IEC 1212-2 6.2 | |
Comparative Tracking Index | >= 600 V | >= 600 V | IEC 1212-2 6.4 |
Descriptive Properties | Value | Comments |
---|---|---|
Proof Tracking Index | 500 | IEC 1212-2 6.4 |
Thermal Endurance | 140 T.I. | IEC 1212-2 7.1 |
Water Absorption | < 101 mg | IEC 1212-2 8.2; Test piece 50 x 50 x 10 mm |